Supported Protocols

List of protocols of analog alarm panels supported by CloudSurgard so far


Protocol List

SIA (dc03)

SIA DC03 standard protocol for alarm transmission, level 1.

Contact ID (dc05)

DC09 with 4-digit accounts in types 18 and 98, and 10-digit

Express

Formats 4+1, type 17 or 4+2 in type 27

High Speed / Scantronic

in all its types

  • 2-8-1, 3-8-1,
  • 4-8-1, 4-16-1, 4-24-1 with or without checksum.
  • 5-8-1, 5-16-1, 5-24-1 with or without checksum.
  • 6-8-1, 6-16-1, 6-24-1 without checksum.
  • 5-8-1

FBII Super Fast

Supported all versions with and without checksum

Basic formats N+M

Known by several names: Pulses, SESCOA, Surgard DTMF, etc., both in DTMF emission and in pulses.

  • 3+1, 3+1 with checksum,
  • 3+2
  • 4+1
  • 4+2, 4+2 with checksum,
  • 4+3, 4+3 with checksum

Acron

  • 3/8
  • 4/8

CFSK

  • v2
  • v3

ROBOFON

With and without checksum

This protocol cannot share receiver number with other protocols.

Notes

  • Many of the protocols are heuristically detected, for example the Contact-Id protocol on pulses with adaptive speed detection.

  • The frequencies of the pulse protocols between 1,780 Hz and 1,920 Hz and speeds between 3-4 pps up to 42 pps are detected.

  • In tone protocols, DTMF F prohibited tones are detected and changed to 0xA